Sepmaster 2000 Gas Chromatograph

Link Copied
5 Lac / Piece
Business Type Supplier, Distributor
Gas Chromatograph brochure View
Country of Origin India
Warranty 1year
Click to view more

Product Details

Size
28x30x18cm
Temperature Range Indoor
+5~42 Degree C
Temperature Setting
1 Degree C the Programmed Heating Rate 0.1 Degree C
Maximum Heating Speed
120 Degree C / Min
Temperature Programming
7 Class
The Maximum Control Temperature
400 Degree C
Detect Index
Flame ionization detector(FID)
Injection Port
A Variety of Injection Port Can Match:packed Column Injection Port, Shunt/not Bypas
Temperature Stability
When Environment Temperature Change 1 Degree ,Is 0.01 Degree C

Features:

\\n
    \\n
  • High precision, Multi-function, connects the international advanced technology
  • \\n
  • Unique design sampling system, can lower detection limit
  • \\n
  • Can be installed hydrogen flame ionization detector (FID), pool thermal conductivity detector (TCD), electron capture detector (ECD), flame photometric detector (FPD), nitrogen and phosphorus detector (NPD), photoelectric ionization detector (PDHID) of six kinds of detector.
  • \\n
  •  Thermal conductivity cell detector (TCD) stable time: ≤10 min
  • \\n
\\n

Specifications:

\\n
    \\n
  • LOD(limit of detection): ≤5×10-12g/s   [n-C16]
  • \\n
  • drifting: ≤5×10-13A/30min
  • \\n
  •  noise: ≤2×10-13A
  • \\n
  • linear dynamic range : ≥107
  • \\n
  • thermal conductivity cell detector(TCD)
  • \\n
  • The maximum control temperature: 400???
  • \\n
  • sensitivity: ≥10000mv.ml/mg   [n-C16]
  • \\n
  • drifting: ≤100uV/30mi
  • \\n
  • noise: ≤20uA
  • \\n
  • linear dynamic range: ≥105
  • \\n
  • Electron capture detector(ECD)
  • \\n
  • The maximum control temperature: 350???
  • \\n
  • LOD(limit of detection): ≤6×10-15 g/ml    (γ-666)
  • \\n
  • drifting: ≤50uV/30min
  • \\n
  • noise: ≤20uV
  • \\n
  • linear dynamic range: ≥104
  • \\n
  • Flame photometric detector(FPD)
  • \\n
  • The maximum control temperature: 400???
  • \\n
  • LOD(limit of detection):  ≤2×10-13g/s(P)     ≤5×10-11g/s(S)
  • \\n
  • drifting:  ≤4×10-11A/30min
  • \\n
  • noise:  ≤2×10-12A
  • \\n
  • linear dynamic range:   ≥103(P)      ≥102(S)
  • \\n
  • Nitrogen and phosphorus detector(NPD)
  • \\n
  • The maximum control temperature: 400???
  • \\n
  • LOD(limit of detection): ≤5×10-13g/s(P)       ≤1×10-12g/s(N)
  • \\n
  • drifting: ≤25×10-12A/30min
  • \\n
  • noise: ≤4×10-13A
  • \\n
  • linear dynamic range: ≥103(P)
  • \\n
  • Photoelectric ionization detector(PDHID)
  • \\n
  • LOD(limit of detection): ≤5ppb
  • \\n
  • Application
  • \\n
  • Petroleum, chemical, food, pharmaceutical, environmental protection, for disease control and prevention, safety, water, electricity, metallurgy, scientific research institutes, quality inspection department.
  • \\n

Yes! I am interested


Looking for "Sepmaster 2000 Gas Chromatograph" ?

Piece

Explore More Products



Close

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us