Laboratory Analyzers

Leading Manufacturers, Exporters, Wholesaler, Retailer and Trader of Atomic Absorption Spectrophotometer, Carbon Sulphur Analyser, Coating Thickness Spectrometer, Colour Measuring Spectrophotometer, Desktop Xrf Spectrometer, Flow CAM Dynamic Imaging Particle Size & Shape Analyzer, Multi Parameters Universal Spectrometer, Nitrogen Oxygen Hydrogen Analyzer, Quantum Gold Pro Oes Spectrometer and Wdx Spectrometer from Delhi.

Business Type Supplier
Atomic Absorption Spectrometer View
Country of Origin India
Mobility Benchtop
Feature Solaar Software
Wavelength Range 900 Nm
Usage / Application Laboratory use
Band Width 0.2 to 2.0 Nm (automatic)
Detector High Performance Photo Multiplier Tube Sourced from Hamamatsu Japan
Grating Monochromator with blazed at 250 nm holographic grating 1800 lines / mm sourced from Richardson U.S.
Connectivity Standard USB
Installation Accessory As per Site Need
Background correction Background correction D2 arc lamp 190-425 nm modulation up to 1024 Hz
Air Purifier Moisture Trap Filter with Regulator
Data Processing Pc Data Processing / Auto Control System & Printer
Chopper Technology Real Time Chopper Positioning System -rtcps
Electrical Parameter 220 V +/- 10 V Basic unit 600VA
Dimension 868x525x520 mm (LXWXH)

Click to view more

Product Description:

 

  • Excellent performance / price ratio
  • Advanced built-in graphite furnace power supply
  • Can be equipped with a graphite furnace auto sampler
  • Durable graphite tube, can be used for a long time at under 2000 ℃
  • Maximum 20 segment graphite furnace temperature program
  • Powerful software that features easy-to-use method parameter setup and advanced calibration curve fitting
  • Unique background reduction design that allows for accurate analysis of high salinity, high background samples such as soy sauce, food, etc.

 

Product Details:

 

  • Built-in computer data processing and liquid crystal display: A highly integrated PC-based digital circuits, stable and reliable. It has integral to maintain, peak height, peak area, automatic zero adjustment, deuterium lamp background deduction, a variety of linear and nonlinear curve fitting, the screen shows the various parameters and working curves, print reports and other functions, also with an external personal computer interfaces.

 

  • Reliable baseline stability: dual-beam system of optimal design can compensate light source drift, wavelength drift caused by temperature changes (with the function of eliminating the baseline stability caused by wavelength drift) and the electronic circuit drift, therefore, has a reliable baseline stability.Cathode lamps can analyze sample immediately without long-term is firstly chosen equipment for users to analyze the various elements and rapid analysis of samples

 

  • High precision: Gas system can ensure high precision of test and low concentration as it is equipped with sophisticated regulation, steady flow devices, the thin beam of unique designed running through the flamite is stable flame and low noise.

 

  • High-energy light path: reflective optical system, the whole waveband achromatic. Transform optically the circular light beam into a long beam and run into the slit, thus enhancing the optical flux of two-beams.

 

  • Long-life corrosion-resistant atomic system: combustion head is made of new titanium alloy material which is corrosion-resistant, fast heat balance , can achieve measurement sensitivity stability no water cooling.

 

  • Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.

 

  • Safe and reliable gas system: fast gas switching and security guards, can make the analysis of air - acetylene flame as well as flame, expanding the elements to more than 60 species.

 

Performance:

 

  • Working spectral band:190 nm-900 nm
  • Wavelength accuracy:≤±0.5 nm
  • Wavelength repeatability:≤0.3 nm(single direction)
  • Spectrum bandwidth :0.1/0.2/0.7/2.0 nm automatically switch
  • Baseline stability:≤0.004 Abs/30 min
  • Background calibration ability: >30 times



Additional Information:

  • Item Code: JK-AAS-320N
Read More...


Request to Call


Business Type Supplier, Retailer
Country of Origin India
High Frequency Induction Furnace LC: 0.0001% - 0.2% HC: 0.2%-6% LS: 0.0001% - 0.3% HS: 0.3%-30%
Tubular Resistance Furnace C: 0.01% -100% S: 0.005% -100%*
Sensitivity Carbon and Sulfur: 0.01ppm
Analysis Time 40-60 seconds -150-300 seconds
Power Supply 230VAC +/-10%,50/60Hz,16A
Chemical Reagent Magnesium perchlorate,CO2 absorbent
Dimension 55x77x76cm(WxHxD)
Specimen Weighting High Frequency Induction Furnace: 0.1g-0.5g Tubular Resistance Furnace: 400mg/coal
Power Gas Nitrogen or Compressed Air
Carrier Gas Oxygen 99.5%, 3L/min

Click to view more

NCS fully Automtic Carbon & Suphur Analyzer for highly accurate analysis of carbon and sulphur in Blast Furnace 

Read More...


Request to Call


Business Type Supplier, Retailer
Condition New
Power Source Electric
Display Type Digital
Country of Origin India
Tube Voltage 5 - 50 KV
Test Time 30 Seconds
Ambient Humidity Less than 71%
Ambient Temperature -20 DegreeC - +50 DegreeC
Measurable Elements From Sodium to Uranium (76 Element Total)
Precision 0.05% - .1% Deviation
Power Input 110 V AC or 220 V AC
Mobility Benchtop
Sensitivity Superior Accuracy
Usage/ Application General Metal Analyser

Click to view more

Hitachi coating thickness analyzer provides coating thickness of multilayers in ppm levels  

Read More...


Request to Call


Business Type Supplier, Trader, Distributor
Country of Origin India
Wavelength Range 360-740 nm
Optical System Single Beam
Mobility Portable
Spectral Bandwidth 4 nm
Model No / Item Code Nh 310
Photometric Accuracy 0.005 Abs At 0 - 0.5 Abs
Display Type Tft Wvga Color Graphic Touch Screen
Interfaces 2x Usb Typ A, 1x Usb Typ B, 1x Ethernet
Logging Memory 100 Colour References1000 Photometric Values20 Wavelength Scans20 Time Scans 3000 Colour Readings
Display Resolution 480 - 800 pixel
Optical Path Length 10 - 50 mm
Includes Cell Adapter, Dust Cover, Power Supply, User Manual
Wavelength Reproducibility Less than 0.1 nm
Operating temperature Range 10 - 40 degree C
Weight 4.2 kg
Manual Languages English, French, German, Italian
Display Size 17.8 Cm (7 In.)
Max. Operating Humidity 80 %
Max. Storage Humidity 80 %
Dimensions (h X W X D) 151 Mm X 350 Mm X 255 Mm

Click to view more

We Iza Analytics, are top  notch suppliers of Color Spectrophotometers.

Read More...


Request to Call


Business Type Manufacturer, Supplier, Retailer
Condition New
Tube Voltage 5 KV-50 KV
Element Contents 1 ppm - 99.99%
Analysis of Elements. 24
Analysis Accuracy 0.05%
Measurement Time 60s-200s
Energy Resolution 150 +/- 5 eV
Tube Current 50 uA-1000 uA
Mobility Benchtop
Usage/ Application Laboratory use
Sensitivity superior accuracy
Forms of Samples Powder, solid and liquid
Ability of Simultaneous Analysis Simultaneously
Measurable Elements Na to U.

Click to view more

Product Details :-

The halogen –free plan with the new round environmental protection tide is the afforested policy which is greatly promoted by International Green and Peaceful Organization and supported by numerous international environmental protection organizations and international large-scale companies. The European Union 2002/95/EC Instruction, “Montreal Protocol”, “the Stockholm Treaty” and the board material laws and regulations of National Electrician Committee (IEC) have restricted on the halogen material. And, IEC 61249-2-21 in IEC laws and regulations stipulates that the maximum limit of chlorine, bromine and the overall halogen is: bromine and chlorine is less than 900 ppm respectively; (bromine + chlorine) is less than 1500 ppm.
Jiangsu Skyray Instrument Inc. specializes in high-performance X-ray Fluorescence Spectrometers in the world. EDX 3600 H, desktop, Non-halogen analysis spectrometer, introduced in 2009, is of high performance and high-technology halogen testing instrument. The technology, adopting the worldwide leading non-halogen analysis technology, equipped with the best intelligent vacuum system for non-halogen testing and using low energy X-ray to excite light element, thus solve testing problem of chlorine and bromine. The instrument can detect any products containing hazardous substance halogen. In addition, it can be used in all element and RoHS analysis. The instrument is of multi-functional and can meet the international newest standard.

Performance characteristics:

  • Made in USA, halogen testing, X-ray tube of high efficient; the specification reaches the international advanced level.
  • Special accessories are developed for testing halogen element (especially chlorine element)
  • S100 detector, excellent energy linearity, energy resolution and energy spectrum characteristics. Higher peak-to-background ratio.
  • Skyray instrument patent product- Signal-Noise-Enhancer (SNE) improves the signal processing ability up to 25 times.
  • Low energy X-rays are used, delivering good results when exciting light elements such as CI, Br.
  • Intelligent pumping vacuum system; shield air influence and enlarge testing scope.
  • Auto spectrum stabilizer ensures the instrument working.
  • High SNR electronic circuit unit
  • Auto collimator and filter switch, exempt from trouble by manual.
  • Spectrum unfolding technology decomposes the spectrum peak; ensuring CI, Br and other light elements testing have the equal analysis accuracy.
  • Multiple linear regression, reducing the inter elemental absorption and enhancement effect
  • In-built CCD with high resolution
  • LCD makes the important parameter (tube voltage, tube current, vacuum) of the instrument obvious.

Application fields:

  • Non-halogen testing All element analysis/RoHS testing/ Plating thickness
Read More...


Request to Call


Business Type Supplier, Trader, Distributor
Condition New
Country of Origin India
Usage/Application Laboratory Use
Model Name/Number Flowcam
Frequency 50 HZ
Voltage 220V
Type Particle Size & Shape Analyzer
Features Measures Particle Size And Shape, Provides Superior Image Quality, Gives Statistically Relevant Results Quickly, Allows Automated Particle Characterization, Delivers Accurate Results On Particles From 2 µm To 2 Mm

Click to view more

Features:

  • Measures particle size and shape: Collect over 30 measurements on each particle imaged for a more comprehensive analysis.
  • Provides superior image quality and image-based measurements: Fast and accurate results you can see, backed by the quantitative data to prove it.
  • Gives statistically relevant results quickly: You can capture tens of thousands of particle images per minute.
  • Allows automated particle characterization based on statistical pattern recognition: Saves you time by automatically separating different types of particles into user-created libraries.
  • Delivers accurate results on all particles from 2 µm to 2 mm.
Read More...


Request to Call


Business Type Supplier, Trader, Distributor
Driven Type Electric
Color Black
Country of Origin India
Input Supply Voltage 230V
System Requirements Windows 2000 and higher
Output MHV connector
Control USB 2.0
Frequency 50Hz
High voltage 0 to +2048 volts, computer controlled in 2 volt increments

Click to view more

Product Details :-


RIUS Universal Spectrometer 
is a latest State-of-the-art & Unique Spectrometer capable of Absorbance, Transmittance, Fluorescence and Irradiance measurement in a single instrument. Our product is extremely employed in Research & Q.C labs due to their versatility. compactness & extraordinary performance utilizing military grade components for longer life.

 

Features:-

  • Absorbance, Concentration, Fluorescence & Irradiance measurement
  • Affordable rate
  • Flawless finish
  • Durable nature
  • Low maintenance
  • Longer service life
Read More...


Request to Call


Business Type Manufacturer, Supplier, Retailer
Frequency 50 +- 1 Hz
Oxygen 0.1 ~ 300ppm
Hyperoxia 0.03% ~ 2%*
Nitrogen Low Nitrogen: 0.1 ~300ppm, High Nitrogen: 0.03% ~ 2%
Hydrogen Low Hydrogen: 0.1-50ppm High Hydrogen: 50-1000ppm
Sensitivity 0.01ppm
Pulse Furnace Current 0 ~ 1500A,
Power 7.5kVA, maximum
Temperature Higher Than 3000 degree C.
Voltage 220 VAC +/- 10%
Size W X H X D: 55cm X 65cm X 65cm

Click to view more

NCS N/O/H Gas Analyzer for big steel plants with VOD process used for refining steel 

Read More...


Request to Call


Business Type Manufacturer, Supplier, Retailer
Voltage 230 VAC
Warranty 1year
Condition New
Power Source Electric
Automation Grade Automatic
Type Spectrometers
Country of Origin India
Size 750x510x230 mm
Operating Temperature 15 to 30 Degree C
Storage Temperature 10 to 70 Degree C
Use in Laboratory

Click to view more

We are amongst the leading distributors of impeccable and reliable foreign brands offering a wide range of OES Spectrometer equipped with PMT or CCD based Detectors for any matrices required in Fe and Non-Fe metals eg. low alloy steels, SS, Cast Iron, Tool Steels, Al-Si Alloys, Al-Si-Mg Alloys, Brasse Bronze, Soldiers, Cu Alloys, Zamak Alloys, Lead/Battery Alloys, Inconel, Monel, Haste Alloys and Titanium Alloys etc.

In order to live up to this reputation, we engage in the utilization of high military grade raw materials and modern machines, in compliance with the set industry norms and guidelines. This ensures the excellent products performance and longer service life. Further, the range is quite reasonably priced.

Features:-

  • Precise
  • Accurate
  • Extremely stable
  • User friendly operation
  • Almost zero down time
  • High performance instrument
  • Lowest possible maintenance
  • Lowest possible running costs


Other Details:-

  • We understand the importance of 'zero down-time' and the extent of damage caused due to instrument failure
  • The analysis software (Analysis Suite) provided with the instrument is designed to be operated by a layman with little or no experience in working with computers The software is based on a 'control panel-like' interface which requires the operator to punch only a few 'buttons' to perform an analysis and print reports
  • The 'Quanta-Spec OES has been launched only after extensive lab testing and exhaustive field trials so that our customers reap the benefits of high productivity
  • NCS Model Spark CCD 6000 or LabSpark 750 PMT base OES is equipped with Vacuum optics for total inertness which can be configured for Nitrogen Analysis iSteel along with various other matrices to provide an exceptional performance upto 3-4 decimal detection for trace elements.


Specifications:-

  • Weight and Dimensions: 35 kg (Approx), Instrument size 750 x 510 x 230 mm (W x D x H)
  • Electrical Requirements: 230 V AC, 50 Hz Maximum 320 VAC
  • Environmental Requirements: Operating temperature 5 to 37 degree C ( 40 to 95 degree F), Storage temperature -10 to 70 degree C (14 to 158 degree F)

Size: 750x510x230 Mm.

Read More...


Request to Call


Business Type Supplier, Trader, Distributor
Mobility Fixed
Country of Origin India
Condition New
Power Source Electric
Automation Grade Automatic
Application Industrial Use, Laboratory Use
Model Name/Number WDX
Sensitivity superior accuracy
Usage/ Application Laboratory use
X- Ray Tube 400w Thin Be End Window X-ray Tube Made By Varian
Analysis Accuracy N-1 (24 Hours, Percentage Content) Less Than 0.05%.
Temperature Control Precision In Constant Temperature Chamber Setting value +/-0.1 degree C.
High Voltage Supply 400w (50kv8ma)
Gas Flow System High-accuracy Gas Density Stabilizer with Pressure Stability Up to +/-0.003 Kpa.
Singe Sample Measurement Time Less Than 3-5 Minutes;

Click to view more

Product Details :
Introduction WDX Spectrometer is a powerful tool that has built in 9 fixed proportional Counter Detectors for the analysis of the elements you choose, with an amazing accuracy and 1 Si Pin Detector to test all other elements. With our simple software and technical capabilities, where most testing takes very long, our process is very simple because it incorporates both XRF methods in one. With a new multi channel digital processor, it has greatly improved the measurement accuracy and stability.

Technical Specifications

  • Na, Mg, Al, Si, S, Cl, K, Ca, Fe, P or Ti (Fixed), S - U (EDXRF)
  • Precision: 0.05% (24 Hours)/li>
  • 400 W High Voltage Power
  • Tube: 400 W Be end window X-ray Tube
  • Gas Flow Proportional Detector + Sealed Proportional Detector
  • Independent Vacuum Pumping Structure
  • Multi-Channel MCA real-time detection system
  • 10 paths of 1024-channel independent pulse height analyzer

What do you get?

  • WDX-400 Wavelength Dispersive X-ray Fluorescent Spectrometer
  • Necessary Wiring
  • Computer + 20" Monitor - FREE
  • Silver, Copper Standard Samples
  • Proprietary Software - FREE
  • 1 Year Limited Warranty
Read More...


Request to Call




Looking for Product Name ?

Close

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us